Shippers

Prisma

  • The daily capacity tariff can be calculated as follows: daily factor * monthly factor * yearly tariff

    • Daily factor is always 1/30
    • Monthly factor:
      * In case of FORWARD FLOW depends on month:
      - 0,3 for December, January, February (winter months)
      - 0,15 for march, April, October, November (shoulder months)
      - 0,075 for May, June, July, August, September (summer months)
      * In case of BACKHAUL
         - Monthly factor is 1/12 for all months
    • Yearly tariff can be found on our website

    The costs for a daily FIRM capacity booking can be calculated as: 
    cost (€/day) =  booked daily capacity (kWh/h) * daily tariff (€/kWh/h/Day)

    If the booking is INTERRUPTIBLE, then a discount of 30% will be applied: 
    cost (€/day) =  0,7 * booked daily capacity (kWh/h) * daily tariff (€/kWh/h/Day)

  • The monthly tariff can be calculated as: monthly tariff = monthly factor * yearly tariff

    • Monthly factor:
      * in case of FORWARD FLOW depends on month:
         - 0,3 for December, January, February (winter months)
         - 0,15 for March, April, October, November (shoulder months)
         - 0,075 for May, June, July, August, September (summer months)

      * in case of BACKHAUL
         - Monthly factor is 1/12 for all months
    • Yearly tariff can be found on our website

    The costs for a monthly FIRM capacity booking can be calculated as:
    cost (€/month) =  booked daily capacity (kWh/h) * monthly tariff (€/kWh/h/month)

    No Interruptible products.

  • The quarterly tariff can be calculated as: quarterly tariff = quarterly factor * yearly tariff

    • Quarterly factor:
      * in case of FORWARD FLOW depends on the quarter of a gasyear (Oct – Oct):
         - 0,6 for Q1 (October, November, December)
         - 0,75 for Q2 (January, February, March)
         - 0,3 for Q3 (April, May, June)
         - 0,225 for Q4 (July, August, September)
      * No BACKHAUL product
    • Yearly tariffs can be found in TSC Appendix 1a en 1b

    The costs for a quarterly FIRM capacity booking can be calculated as:
    cost (€/quarter) =  booked quarterly capacity (kWh/h) * quarterly tariff (€/kWh/h/quarter)

    No Interruptible products.

  • The costs for a yearly FIRM capacity booking can be calculated as:
    cost (€/year) =  booked yearly capacity (kWh/h) * yearly tariff (€/kWh/h/year)

    No Interruptible and/or backhaul products.

  • The Within Day capacity can be calculated as follows: the Daily capacity tariff times the Within Day factor.

    The Within Day factor is determined on the number of hours the capacity is made available(runtime): number of hours/24.